My strategy is a deep cycle car battery and harbor freight inverter to run the blower motor. You get a long enough extension cord and you can use your car as an
by pokeymcsnatch 3y ago
My strategy is a deep cycle car battery and harbor freight inverter to run the blower motor. You get a long enough extension cord and you can use your car as an emergency generator.
- brk 3y agoI have done exactly that - car as generator, during a long power outage in NH. We had 2 oil furnaces, and ~350 gallons of oil left in the tanks, but no power to run the blower motors to move the air. A Harbor Freight inverter and our Ford Explorer kept things running for 30 hours, until Amazon could deliver me an 8,000 watt portable generator. The blower motors are pretty power hungry, on the order of about 330 watts, give or take. For a 12V system that is about 30 amps, or about 2 hours of output from a typical deep cycle batter before you risk depleting it to the point of damage. An ~$300 12V Lifepo4 battery might get you 4 hours of runtime, but not much more than that. In most cases, an outage of less than 8 hours won't get things so cold in a decently insulated house that you need to worry about it, and IME, an outage that lasts more than 8 hours has high probability of lasting much much longer. TL;DR - Your deep cycle battery approach may not prove to actually be worthwhile, consider working out the car-as-generator hookup plan in advance.
- pokeymcsnatch 3y ago> TL;DR - Your deep cycle battery approach may not prove to actually be worthwhile, consider working out the car-as-generator hookup plan in advance. Ha yep, learned that the first time and was ready to go with an extension cord the second time I needed this setup. First time, I had a stash of 3 batteries but I didn't realize how much power the blower motor would draw, so I was charging on the car and swapping out batteries as needed. Did that the first day then rigged up cords for day 2. Halfway through day 3 we got power back.
- jcadam 3y agoI have a 7500W dual-fuel generator but haven't gotten around to installing a transfer switch yet. I have a well pump and a gas boiler that I really miss when the power is out :) Radiant in-floor heat is pretty efficient (and it's nice not to have an ice-cold floor first thing in the morning), just need power for the circulation pumps and the boiler. My back up heat is a wood-burning stove - and we have lost power for several hours when the temps are -20F or so...
- voisin 3y ago> power for the circulation pumps and the boiler If the boiler is in the basement would you not be able to treat the circulation tubes as a thermosiphon, with the hot water rising from the boiler, creating pressure to push water through the loop?
- voisin 3y ago> The blower motors are pretty power hungry, on the order of about 330 watts, give or take. For a 12V system that is about 30 amps, or about 2 hours of output from a typical deep cycle batter before you risk depleting it to the point of damage. An ~$300 12V Lifepo4 battery might get you 4 hours of runtime, but not much more than that. This is 2-4 hours of run time though. My experience is that the blower turns on for a period and then off for a period. It would depend on your heat loss rate which is situation specific, but you can probably get significantly more than this in time coverage with the blower only running periodically.